今天碰到一個網(wǎng)絡故障,說網(wǎng)絡有延遲,時斷時通,拓撲如下:
到達現(xiàn)場后,發(fā)現(xiàn)華為7703交換機的所有接口燈都在快閃,懷疑肯定為數(shù)據(jù)風暴,用CONSOLE登陸7703交換機,使用dis inter 查看每個端口的流量情況,上圖中紅圈的三個接口流量如下:
GigabitEthernet1/0/25 current state : UP
Last 300 seconds input rate 7888 bits/sec, 8 packets/sec
Last 300 seconds output rate 4428376 bits/sec, 6406 packets/sec
Input peak rate 643674664 bits/sec, Record time: 2013-11-01 18:07:09
Output peak rate 117703648 bits/sec, Record time: 2013-12-27 15:15:31
GigabitEthernet1/0/26 current state : UP
Last 300 seconds input rate 1837472 bits/sec, 855 packets/sec
Last 300 seconds output rate 5313232 bits/sec, 7230 packets/sec
Input peak rate 150745696 bits/sec, Record time: 2013-12-26 12:38:59
Output peak rate 106835632 bits/sec, Record time: 2013-12-26 12:38:57
GigabitEthernet1/0/27 current state : UP
Last 300 seconds input rate 64968 bits/sec, 58 packets/sec
Last 300 seconds output rate 4690120 bits/sec, 6614 packets/sec
Input peak rate 103824952 bits/sec, Record time: 2013-12-20 13:34:27
Output peak rate 446716152 bits/sec, Record time: 2013-12-27 14:57:26
上圖紅字可看出,三個端口的output流量都在每秒6000左右個數(shù)據(jù)包。從我之前寫的input與output的理解一文可得出,每秒在向接在這三個端口上的服務器發(fā)送6000左右的數(shù)據(jù)包。確定為數(shù)據(jù)風暴了。
立即查找風暴的源頭在哪里,查看華為7703的上聯(lián)口流量:
XGigabitEthernet2/0/3 current state : UP
Last 300 seconds input rate 8796448 bits/sec, 8459 packets/sec
Last 300 seconds output rate 324280 bits/sec, 331 packets/sec
果然,從上紅色字可看出,上聯(lián)華為9312交換機每秒向華為7703交換機發(fā)送8000多個數(shù)據(jù)包,源頭肯定在上華9312交換機上。
在CONSOLE登陸至9312上,使用DIS INTER 查看每個端口的流量,終于發(fā)現(xiàn)有個端口流量異常,如下紅字所示,9312上的8/0/36口正在每秒接收到來自上聯(lián)的華為3700交換機20萬多個包。致使整個網(wǎng)絡癱瘓。
[Center_S9312_01]dis interface g8/0/36
GigabitEthernet8/0/36 current state : UP
Line protocol current state : UP
Last 300 seconds input rate 154218808 bits/sec, 204973 packets/sec
Last 300 seconds output rate 93448 bits/sec, 94 packets/sec
Input peak rate 187223368 bits/sec, Record time: 2013-12-31 11:51:13
Output peak rate 1508304800 bits/sec, Record time: 2013-12-12 10:32:28
立即將8/0/36端口的光纖拔掉,網(wǎng)絡立即恢復正常。
至于3700交換機哪個口有問題,也可以用DIS INTER然后通過查看端口的流量來判斷。